|
Alpha Diagnostics
rabbit anti cx40 19 Rabbit Anti Cx40 19, supplied by Alpha Diagnostics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/anti+eaac1+eaat3+polyclonal+primary+rabbit/pm42252105-104-32-35 Average 86 stars, based on 1 article reviews
rabbit anti cx40 19 - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
|
Alpha Diagnostics
anti mouse cx40 rabbit polyclonal antibody Anti Mouse Cx40 Rabbit Polyclonal Antibody, supplied by Alpha Diagnostics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/anti+eaac1+eaat3+polyclonal+primary+rabbit/us12625147-257-21-26 Average 86 stars, based on 1 article reviews
anti mouse cx40 rabbit polyclonal antibody - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
|
Boster Bio
cx40 polyclonal antibody ![]() Cx40 Polyclonal Antibody, supplied by Boster Bio, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/Anti-Connexin+40%2FGJA5+Antibody+Picoband/pmc13077975-43-36-40 Average 94 stars, based on 1 article reviews
cx40 polyclonal antibody - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
Santa Cruz Biotechnology
anti cx40 ![]() Anti Cx40, supplied by Santa Cruz Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/connexin+40+Antibody/pmc12562952-84-36-38 Average 93 stars, based on 1 article reviews
anti cx40 - by Bioz Stars,
2026-11
93/100 stars
|
Buy from Supplier |
|
Thermo Fisher
anti cx40 polyclonal antibody ![]() Anti Cx40 Polyclonal Antibody, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/Racks+for+Matrix+2D+Barcoded+Storage+Tubes/pmc12332205-93-23-27 Average 95 stars, based on 1 article reviews
anti cx40 polyclonal antibody - by Bioz Stars,
2026-11
95/100 stars
|
Buy from Supplier |
|
Thermo Fisher
rabbit polyclonal anti cx40 gja5 ![]() Rabbit Polyclonal Anti Cx40 Gja5, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/Racks+for+Matrix+2D+Barcoded+Storage+Tubes/pmc12289313-345-39-42 Average 95 stars, based on 1 article reviews
rabbit polyclonal anti cx40 gja5 - by Bioz Stars,
2026-11
95/100 stars
|
Buy from Supplier |
|
Biotrend Chemicals
anti-cx40 ![]() Anti Cx40, supplied by Biotrend Chemicals, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/anti+cx40/pm40429968-336-9-11 Average 90 stars, based on 1 article reviews
anti-cx40 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Thermo Fisher
cx40 ![]() Cx40, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/anti+cx40+antibody/Racks+for+Matrix+2D+Barcoded+Storage+Tubes/pm40360739-168-4-5 Average 95 stars, based on 1 article reviews
cx40 - by Bioz Stars,
2026-11
95/100 stars
|
Buy from Supplier |
Journal: Respiratory Research
Article Title: An improved precision-cut lung slices technique for pulmonary vasoconstriction
doi: 10.1186/s12931-026-03600-x
Figure Lengend Snippet: Acute hypoxia experiment in PCLS. A , Blood vessel morphology in the control group was recorded under the bright-field microscope at the beginning of perfusion, and 40 mM potassium chloride solution was added after the normoxic perfusion was completed. And the subsequent immunofluorescence staining was conducted to determine CX40 expression (right). B , The vascular morphology image in the hypoxic group was recorded in the same way while hypoxic perfusion solution with 1% oxygen was used at the fifth minute after the normmoxic perfusion, and the final exposure to 40 mM potassium chloride solution. And the subsequent immunofluorescence staining was conducted to determine CX40 expression (right). The vessel area was marked with a red dashed line; scale bar: 100 μm (A and B). Due to coverslip mounting required for immunofluorescence staining, the vascular morphology in 200 μm-thick PCLS exhibited slight morphological changes (A and B, right). C , The statistical comparisons of the alteration of vascular area recorded every minute during the entire 35-minute perfusion process, n=4 for each
Article Snippet: Gelatin (porcine skin, type A, 300 g Bloom, Vetec), Cell Tracker CM-DiI (Yeasen Biotechnology, 40718ES50), low melting point agarose (CAS 9012-36-6), tissue perforator (GLOBALEBIO), Penicillin-Streptomycin (1%, Gibco), WST-1 Cell Proliferation and Cytotoxicity Assay Kit (Biyuntian, C0035),
Techniques: Control, Microscopy, Immunofluorescence, Staining, Expressing
Journal: Respiratory Research
Article Title: An improved precision-cut lung slices technique for pulmonary vasoconstriction
doi: 10.1186/s12931-026-03600-x
Figure Lengend Snippet: Immunofluorescence and H&E staining images of pulmonary artery and vein in consecutive paraffin sections. A , CX40 (green) and α-SMA (red) were expressed in artery, whereas only α-SMA (red) in vein. B , Venous and arterial tissue demonstrated in hematoxylin-eosin staining in mouse lung tissue sections. Scale bar: 50 μm
Article Snippet: Gelatin (porcine skin, type A, 300 g Bloom, Vetec), Cell Tracker CM-DiI (Yeasen Biotechnology, 40718ES50), low melting point agarose (CAS 9012-36-6), tissue perforator (GLOBALEBIO), Penicillin-Streptomycin (1%, Gibco), WST-1 Cell Proliferation and Cytotoxicity Assay Kit (Biyuntian, C0035),
Techniques: Immunofluorescence, Staining
Journal: Respiratory Research
Article Title: An improved precision-cut lung slices technique for pulmonary vasoconstriction
doi: 10.1186/s12931-026-03600-x
Figure Lengend Snippet: Immunofluorescence and H&E staining images of consecutive paraffin sections. A , CX40 (green) and α-SMA (red) were expressed in both pulmonary artery and bronchus. B , bronchus and arterial tissue structures demonstrated by hematoxylin-eosin staining in mouse lung tissue sections. Scale bar: 50 μm
Article Snippet: Gelatin (porcine skin, type A, 300 g Bloom, Vetec), Cell Tracker CM-DiI (Yeasen Biotechnology, 40718ES50), low melting point agarose (CAS 9012-36-6), tissue perforator (GLOBALEBIO), Penicillin-Streptomycin (1%, Gibco), WST-1 Cell Proliferation and Cytotoxicity Assay Kit (Biyuntian, C0035),
Techniques: Immunofluorescence, Staining
Journal: Biomolecules
Article Title: Trandolapril Attenuates Pro-Arrhythmic Downregulation of Cx43 and Cx40 in Atria of Volume Overloaded Hypertensive and Normotensive Rats
doi: 10.3390/biom15101457
Figure Lengend Snippet: Protein levels of Cx43 ( A ) and Cx40 ( B ) normalized to GAPDH assessed by Western blot analysis. Hypertensive TGR rats exhibited lower levels of Cx43 and Cx40 in both the left and right atria compared to normotensive rats. A pronounced decrease in Cx43 and Cx40 protein levels was observed in both atria of normotensive HSD and hypertensive TGR rats due to volume overload. Treatment with an ACEi increased Cx43 and Cx40 levels ( p > 0.05) in both atria of volume-overloaded normotensive and hypertensive rats. In contrast, ARB treatment increased Cx43 but did not affect Cx40 levels in either atrium of volume-overloaded rats. HSD—Hannover Sprague Dawley rats; TGR—Ren-2 transgenic rats; ACF—aortocaval fistula, surgical model of volume overload; ACEi—treatment with the angiotensin-converting enzyme inhibitor, trandolapril; ARB—treatment with an angiotensin II type 1 (AT 1 ) receptor blocker, losartan. n = 10 per group. Data are presented as means ± SD; a p < 0.05 vs. HSD, b p < 0.05 vs. HSD ACF, c p < 0.05 vs. TGR, d p < 0.05 vs. TGR ACF. Western blot original images can be found in .
Article Snippet: Membranes were blocked in 5% low-fat milk ( w / v in TBS-T) for 4 h at room temperature and incubated overnight at 4 °C with the appropriate primary antibodies: anti-total Cx43—1:5000, C6219, Sigma-Aldrich, MI, USA;
Techniques: Western Blot, Transgenic Assay
Journal: Biomedical Journal
Article Title: Endothelial activation, cell-cell interactions, and inflammatory pathways in postoperative atrial fibrillation following cardiac surgery
doi: 10.1016/j.bj.2024.100821
Figure Lengend Snippet: Connexins expression and apoptosis level in a representative tissue sample from each type of patient: permanent AF, POAF and non-AF. Cx40: connexin 40; Cx43: connexin 43. Connexins can be seen in brown between the junctions of the cells. Apoptosis occurs when the nuclei of cardiomyocytes appear brown.
Article Snippet: After endogenous peroxidase and unspecific background blocking, sections were incubated with the corresponding primary antibody diluted in blocking solution overnight at 4 °C (
Techniques: Expressing
Journal: Biomedical Journal
Article Title: Endothelial activation, cell-cell interactions, and inflammatory pathways in postoperative atrial fibrillation following cardiac surgery
doi: 10.1016/j.bj.2024.100821
Figure Lengend Snippet: Connexin levels. A. Cx40. B. Cx43. ∗ p < 0.05 ∗∗ p < 0.01 ∗∗∗ p < 0.001.
Article Snippet: After endogenous peroxidase and unspecific background blocking, sections were incubated with the corresponding primary antibody diluted in blocking solution overnight at 4 °C (
Techniques:
Journal: Communications biology
Article Title: AI-guided laser purification of human iPSC-derived cardiomyocytes for next-generation cardiac cell manufacturing.
doi: 10.1038/s42003-025-08162-0
Figure Lengend Snippet: Fig. 3 | Acute structural and electrical functional analysis of CM-AI purified hiPSC-CM monolayers. a Western blot analysis of atrial-specific CM proteins in purified versus unpurified monolayers. CM-AI + Laser purified monolayers (n = 6, Lanes 1–6) showed significant enrichment of Cx40, cTnI, and mlc2a protein expression compared to time and batch-matched non-purified monolayers. b Cx40 protein expression was significantly enriched in laser-purified hiPSC-CM mono- layers compared to non-purified monolayers (0.73 ± 0.13au; n = 6 vs. 0.08 ± 0.01au; n = 3; ****P < 0.0001, unpaired t-test). c cTnI protein expression was significantly greater in laser-purified monolayers compared to non-purified hiPSC-CM atrial monolayers (0.31 ± 0.09au; n = 6 vs. 0.02 ± 0.01au; n = 3; ***P = 0.0009, unpaired t- test). d mlc2a myofilament protein expression was significantly enriched in laser- purified hiPSC-CM monolayers compared to non-purified monolayers (0.16 ± 0.08au; n = 6 vs. 0.03 ± 0.01; n = 3; *P = 0.04, unpaired t-test). e Atrial hiPSC-
Article Snippet: Primary antibodies used include:
Techniques: Functional Assay, Western Blot, Expressing